{"product_id":"allen-bradley-937th-airrp-dc1-intrinsic-safety-isolator-temp-repeater-24vdc-used-copy","title":"Festo VPPM-6L-L-1-G18-0L6H-A4P-S1C1, 575128 Proportional Valve 3-Way, 0.06-6bar","description":"\u003cdiv class=\"article-summary-top-feature-row-container--jHMR0\"\u003e\n\u003cdiv class=\"article-summary-top-feature-name--bsWXW\" title=\"Valve function\"\u003e\u003cstrong\u003eValve function\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-value--aDlhX\" title=\"3-way proportional pressure control valve\"\u003e3-way proportional pressure control valve\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-row-container--jHMR0\"\u003e\n\u003cdiv class=\"article-summary-top-feature-name--bsWXW\" title=\"Pneumatic connection 1\"\u003e\u003cstrong\u003ePneumatic connection 1\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-value--aDlhX\" title=\"G1\/8\"\u003eG1\/8\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-row-container--jHMR0\"\u003e\n\u003cdiv class=\"article-summary-top-feature-name--bsWXW\" title=\"Pressure regulation range\"\u003e\u003cstrong\u003ePressure regulation range\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-value--aDlhX\" title=\"0.06 bar - 6 bar\"\u003e0.06 bar - 6 bar\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-row-container--jHMR0\"\u003e\n\u003cdiv class=\"article-summary-top-feature-name--bsWXW\" title=\"Normal nominal flow rate (normalized to DIN 1343)\"\u003e\n\u003cstrong\u003eNormal nominal flow rate (normalized to DIN 1343)\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-value--aDlhX\" title=\"900 l\/min\"\u003e900 l\/min\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-value--aDlhX\" title=\"900 l\/min\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-value--aDlhX\" title=\"900 l\/min\"\u003e\n\u003ch3 class=\"technical-data-header--_TG3G\"\u003eTechnical Data Proportional pressure control valve VPPM-6L-L-1-G18-0L6H-A4P-S1C1\u003c\/h3\u003e\n\u003cul class=\"technical-data-table--V_IjZ\"\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eNominal width pressurization\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e6 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eExhaust nominal width\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e4.5 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eActuation type\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eElectrical\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eSealing principle\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eSoft\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMounting position\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eAny\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eStructural design\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003ePilot-controlled diaphragm regulator\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eShort-circuit protection\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eFor all electrical connections\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eSafety instructions\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eVPPM safety position: if the supply cable breaks, the outlet pressure is maintained in uncontrolled form.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eSymbol\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e00995303\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eReverse polarity protection\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003efor all electrical connections\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eReset method\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eMechanical spring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eType of control\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003ePiloted\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eValve function\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e3-way proportional pressure control valve\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eDisplay type\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eBacklit LCD\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePressure regulation range MPa\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.006 MPa ... 0.6 MPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePressure regulation range\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.06 bar ... 6 bar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eInlet pressure 1\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0 bar ... 8 bar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eInlet pressure 1 MPa\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0 MPa ... 0.8 MPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMax. pressure hysteresis\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.03 bar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eNormal nominal flow rate (normalized to DIN 1343)\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e900 l\/min\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eDC operating voltage range\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e21.6 V ... 26.4 V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMax. current consumption\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e300 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eDuty cycle\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e100%\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMax. electrical power consumption\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e7 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eResidual ripple\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e10%\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eAnalog output signal range\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e4 - 20 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePrecision analog output in ± %FS\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e2 %FS\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eAnalog input signal range\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e4 - 20 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eOperating medium\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eCompressed air as per ISO 8573-1:2010 [7:4:4] Inert gases\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eInformation on operating and pilot media\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eOperation with oil lubrication not possible\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eCertification\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eRCM compliance mark c UL us - Listed (OL)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eKC characters\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eKC-EMV\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eCE marking (see declaration of conformity)\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eAs per EU EMC directive As per EU RoHS directive\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eUKCA marking (see declaration of conformity)\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eTo UK RoHS instructions\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eCertificate issuing authority\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eUL E322346\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eCorrosion resistance class (CRC)\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e2 - Moderate corrosion stress\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eLABS (PWIS) conformity\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eVDMA24364-B1\/B2-L\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eTemperature of medium\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e10 °C ... 50 °C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eDegree of protection\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eIP65\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eAmbient temperature\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0 °C ... 50 °C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eProduct weight\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e400 g\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eLinearity\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e1 %FS\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eHysteresis\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.5 %FS\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eReproducibility\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.5 %FS\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eOverall accuracy\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e1.25 %FS\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eTemperature coefficient\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.04 %\/K\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eRepetition accuracy FS\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.5 %\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eElectrical connection\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e8-pin M12 Plug\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eType of mounting\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eAlternatively: With through-hole With accessories\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePneumatic connection 1\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eG1\/8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePneumatic connection 2\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eG1\/8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePneumatic connection 3\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eG1\/8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eNote on materials\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eRoHS compliant\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eHousing material\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eWrought aluminum alloy Anodized\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUsed Working Pull\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":53122442658112,"sku":"575128","price":149.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0688\/0752\/4672\/files\/PXL_20260909_124337266.jpg?v=1788963651","url":"https:\/\/jlsindustrialsurplus.com\/products\/allen-bradley-937th-airrp-dc1-intrinsic-safety-isolator-temp-repeater-24vdc-used-copy","provider":"JLS Industrial Surplus LLC","version":"1.0","type":"link"}